The 8 3/4″ DeBakey Multi-Purpose Aorta Clamp Angled 90° is a precision-engineered cardiovascular surgical instrument designed to provide surgeons with superior control, accessibility, and reliability during aortic and vascular procedures. Based on the trusted DeBakey instrument design, this multi-purpose aortic clamp features a 90° angled jaw configuration that allows improved access to challenging anatomical locations while maintaining secure and controlled manipulation of major blood vessels. Its specialized design makes it an essential tool for cardiovascular surgery, aortic procedures, vascular reconstruction, and other operations requiring accurate vessel occlusion and handling.
The 90° angled jaw design provides exceptional versatility when working in deep or restricted surgical fields. This right-angle configuration allows surgeons to approach the aorta and surrounding vascular structures from an optimal position, improving visualization and reducing the need for excessive tissue retraction. The design supports precise placement and controlled movement, making it particularly useful during procedures where access and accuracy are critical.
Featuring a trusted DeBakey atraumatic jaw pattern, this aorta clamp is designed to provide secure vessel control while minimizing trauma to delicate vascular tissues. The fine serrated jaw surface helps distribute pressure evenly across the vessel, reducing the risk of slipping while maintaining gentle tissue handling. This atraumatic design is especially important during aortic and cardiovascular procedures where preservation of vessel integrity is essential.
With an overall length of 8 3/4 inches, the DeBakey Multi-Purpose Aorta Clamp offers a practical balance between reach, control, and maneuverability. The length provides sufficient access to deeper operative areas while allowing surgeons to maintain precise tactile feedback. Its balanced construction supports smooth handling during critical cardiovascular procedures and helps improve surgical efficiency.
Manufactured from premium surgical-grade stainless steel, this aortic clamp provides outstanding durability, corrosion resistance, and long-term clinical reliability. The high-quality stainless steel construction ensures consistent performance after repeated cleaning, disinfection, and steam autoclave sterilization. Precision manufacturing maintains proper jaw alignment, smooth hinge action, and reliable locking performance throughout extended clinical use. The satin matte finish reduces glare from operating room lighting, improving visibility during delicate surgical procedures.
The ergonomic ring handles are designed for secure and comfortable operation, allowing surgeons to maintain excellent control throughout the procedure. The precision ratchet locking mechanism provides controlled pressure application and secure positioning when required. The smooth box lock hinge ensures effortless opening and closing while supporting dependable performance over time.
The 8 3/4″ DeBakey Multi-Purpose Aorta Clamp Angled 90° is commonly used in cardiovascular surgery, aortic repair, vascular reconstruction, aortic occlusion procedures, bypass surgery, graft placement, thoracic surgery, and complex vascular interventions. Its multi-purpose functionality allows surgeons to perform controlled vessel grasping, temporary occlusion, and manipulation with a single reliable instrument.
Designed for professional surgical environments, this clamp supports strict hospital cleaning and sterilization standards. The stainless steel construction allows thorough cleaning and compatibility with standard steam autoclave sterilization protocols. Its durable design ensures dependable performance in hospitals, cardiovascular centers, and specialized surgical facilities.
Combining the trusted DeBakey design, 90° angled jaw configuration, atraumatic gripping capability, ergonomic handling, and premium stainless steel construction, the 8 3/4″ DeBakey Multi-Purpose Aorta Clamp Angled 90° delivers the precision, control, and durability required for advanced cardiovascular and aortic surgical procedures.
Key Features
- Precision-designed 8 3/4″ DeBakey Multi-Purpose Aorta Clamp
- 90° angled jaws for improved surgical access
- Designed specifically for aortic and vascular procedures
- Atraumatic DeBakey serrated jaws reduce tissue trauma
- Provides secure vessel control and temporary occlusion
- Ideal for cardiovascular and reconstructive surgery
- Premium surgical-grade stainless steel construction
- Ergonomic ring handles for comfortable handling
- Precision ratchet locking mechanism for secure positioning
- Smooth box lock hinge for reliable operation
- Satin matte finish reduces operating room glare
- Reusable and steam autoclavable
Product Specifications
| Specification | Details |
|---|---|
| Product Name | 8 3/4″ DeBakey Multi-Purpose Aorta Clamp Angled 90° |
| Instrument Type | Aortic Surgical Clamp |
| Overall Length | 8 3/4″ (22.2 cm) |
| Jaw Angle | 90° Angled |
| Jaw Design | Atraumatic DeBakey Serrated Jaws |
| Handle Type | Ring Handles |
| Locking Mechanism | Ratchet Lock |
| Material | Surgical-Grade Stainless Steel |
| Finish | Satin / Matte Anti-Glare |
| Reusable | Yes |
| Sterilization | Steam Autoclave Compatible |
| Sterility | Supplied Non-Sterile |
| Specialty | Cardiovascular & Aortic Surgery |
| Application | Aortic Occlusion, Vessel Handling & Surgical Manipulation |
FAQs
1. What is the 8 3/4″ DeBakey Multi-Purpose Aorta Clamp used for?
It is used for aortic and vascular procedures requiring secure vessel control, temporary occlusion, and precise manipulation.
2. What is the advantage of the 90° angled jaws?
The 90° angle provides improved access and visibility in deep surgical fields, allowing surgeons to position the clamp effectively around vascular structures.
3. Are DeBakey aorta clamps atraumatic?
Yes. The DeBakey serrated jaw design provides secure gripping while helping minimize trauma to delicate vascular tissues.
4. Is this aortic clamp reusable?
Yes. It is manufactured from surgical-grade stainless steel and is designed for repeated cleaning, sterilization, and clinical use.
5. Which procedures use this DeBakey aorta clamp?
It is commonly used in aortic repair, cardiovascular surgery, vascular reconstruction, bypass procedures, graft placement, and other advanced vascular operations.

Reviews
There are no reviews yet.