The 9 ¾″ Wylie “J” Clamp Jaws 3.2 cm Wide, 2.5 cm Deep is a premium vascular surgical instrument engineered to provide temporary vascular occlusion and controlled handling of major arteries during complex cardiovascular, abdominal, and peripheral vascular procedures. Developed for vascular surgeons, cardiovascular specialists, transplant surgeons, and general surgeons, this specialized Wylie clamp delivers dependable vessel control while minimizing trauma to delicate arterial tissues. Its distinctive J-shaped jaw configuration allows improved access around anatomical structures, making it particularly effective for procedures that require precise vessel exposure and controlled interruption of blood flow.
Reliable vascular occlusion is essential during arterial reconstruction and other advanced vascular procedures. The Wylie “J” Clamp features precision-engineered atraumatic jaws that apply balanced compression across the vessel wall, allowing temporary interruption of blood flow while helping preserve endothelial integrity. The carefully designed jaw geometry minimizes localized pressure points, reducing the risk of vascular injury while supporting safe arterial repair, graft placement, vascular anastomosis, and bypass surgery.
Measuring 9 ¾ inches (approximately 24.8 cm) in overall length, this clamp provides extended reach for deep operative fields commonly encountered during abdominal and pelvic vascular surgery. The longer profile allows surgeons to access major arteries with greater ease while maintaining excellent visibility and precise instrument control. Its balanced construction improves maneuverability around surrounding anatomical structures, contributing to greater surgical efficiency in technically demanding procedures.
The instrument features 3.2 cm wide jaws with a 2.5 cm jaw depth, offering a broad contact surface for secure engagement of major blood vessels. The J-shaped jaw design enables surgeons to approach vessels from advantageous angles while minimizing interference with adjacent tissues. The combination of jaw width and depth promotes even pressure distribution, allowing dependable temporary occlusion while reducing unnecessary stress on the arterial wall. This configuration is particularly beneficial during aortoiliac reconstruction, abdominal aortic aneurysm repair, iliac artery surgery, carotid artery procedures, peripheral arterial bypass, renal vascular surgery, and vascular graft placement.
Manufactured from premium German surgical-grade stainless steel, the 9 ¾″ Wylie “J” Clamp provides exceptional durability, corrosion resistance, and dependable long-term clinical performance. The high-quality stainless steel construction maintains precise jaw alignment, smooth ratchet operation, and structural integrity through repeated cleaning and sterilization cycles. Its satin matte finish reduces glare from operating room lighting while enhancing resistance to corrosion, staining, and surface wear.
The ergonomically designed finger ring handles provide outstanding balance, tactile feedback, and precise control throughout prolonged vascular procedures. A precision ratchet locking mechanism enables surgeons to maintain consistent clamping pressure without continuous hand force, reducing fatigue while ensuring secure vessel occlusion during delicate operations.
The 9 ¾″ Wylie “J” Clamp Jaws 3.2 cm Wide, 2.5 cm Deep is an essential instrument for vascular surgery, cardiovascular surgery, transplant surgery, trauma surgery, and general surgery. It is widely used in hospitals, vascular centers, teaching institutions, and specialty surgical facilities performing arterial reconstruction, aneurysm repair, bypass surgery, vascular trauma management, and complex vascular interventions.
Designed for repeated professional use, this reusable vascular clamp is fully compatible with standard hospital sterilization methods, including steam autoclaving. Combining precision engineering, atraumatic J-shaped jaws, ergonomic handling, and premium stainless steel construction, the 9 ¾″ Wylie “J” Clamp delivers the precision, durability, and reliability required in modern vascular surgery.
Key Features
- 9 ¾″ Wylie “J” Clamp for vascular and cardiovascular surgery
- J-shaped jaws improve access to deep vascular structures
- Jaw dimensions: 3.2 cm wide × 2.5 cm deep
- Precision atraumatic jaws minimize arterial trauma
- Designed for temporary vascular occlusion and arterial reconstruction
- Ideal for bypass surgery, aneurysm repair, and vascular anastomosis
- Extended length provides excellent reach in deep operative fields
- Manufactured from premium German surgical-grade stainless steel
- Satin matte finish reduces operating room glare
- Ergonomic finger ring handles ensure precise instrument control
- Precision ratchet locking mechanism maintains secure clamping pressure
- Fully reusable, corrosion-resistant, and autoclavable
Product Specifications Table
| Specification | Details |
|---|---|
| Product Name | Wylie “J” Clamp |
| Overall Length | 9 ¾ inches (24.8 cm) |
| Jaw Width | 3.2 cm |
| Jaw Depth | 2.5 cm |
| Jaw Style | J-Shaped Atraumatic Jaw |
| Instrument Type | Vascular Clamp |
| Application | Cardiovascular, Vascular, Abdominal & Peripheral Vascular Surgery |
| Material | German Surgical Grade Stainless Steel |
| Finish | Satin Matte Finish |
| Handle Type | Finger Ring Handle |
| Locking Mechanism | Ratchet Lock |
| Sterilization | Autoclavable |
| Reusable | Yes |
| Clinical Use | Professional Surgical Use |
FAQs
1. What is the 9 ¾″ Wylie “J” Clamp used for?
The clamp is used for temporary occlusion of major arteries during vascular reconstruction, aortoiliac surgery, abdominal aneurysm repair, arterial bypass procedures, and vascular anastomosis.
2. What is the advantage of the J-shaped jaw design?
The J-shaped jaws provide improved access to vessels located in deep or difficult anatomical areas, allowing precise placement while minimizing interference with surrounding tissues.
3. Why are the 3.2 cm wide and 2.5 cm deep jaws important?
The wide and deep jaws provide a secure contact surface that distributes pressure evenly across the vessel, helping reduce trauma while maintaining reliable temporary occlusion.
4. What material is the Wylie “J” Clamp made from?
The instrument is manufactured from premium German surgical-grade stainless steel, ensuring superior durability, corrosion resistance, and long-term surgical performance.
5. Is this clamp reusable and autoclavable?
Yes. The clamp is fully reusable and compatible with standard hospital sterilization methods, including steam autoclaving.
6. Which medical specialties commonly use the Wylie “J” Clamp?
The 9 ¾″ Wylie “J” Clamp is widely used in vascular surgery, cardiovascular surgery, transplant surgery, trauma surgery, and general surgery for arterial reconstruction, vascular bypass, aneurysm repair, vascular graft placement, and other procedures requiring precise temporary vessel occlusion.