The Neurosurgery Micro Thin Kerrison Rongeur 1.5mm 40° Up Panther is a high-performance microsurgical bone rongeur engineered to provide exceptional precision during advanced cervical spine procedures. Specifically developed for neurosurgeons and orthopedic spine surgeons, this instrument combines advanced Panther engineering with superior cutting performance, ergonomic handling, and outstanding durability. Featuring a 1.5mm bite, 40° upward-angled jaw, micro-thin Panther profile, and a compact 7-inch (175 mm) overall length, it enables surgeons to perform highly controlled bone and ligament removal within narrow cervical operative fields while maintaining maximum surgical accuracy.
Designed exclusively for cervical spine surgery, this specialized Kerrison Rongeur is commonly used during cervical laminectomy, laminotomy, foraminotomy, cervical spinal decompression, microdiscectomy, and other delicate neurosurgical procedures. The precision 1.5mm bite allows surgeons to remove extremely small portions of lamina, osteophytes, and hypertrophied ligament tissue with remarkable control. This level of precision is particularly important when operating around the spinal cord and cervical nerve roots, where preservation of healthy anatomical structures is essential for optimal patient outcomes.
The 40° upward-angled jaw is specifically engineered to improve access to anatomically challenging areas of the cervical spine. This optimized jaw configuration allows surgeons to approach targeted tissue from an ideal angle while maintaining excellent visualization throughout the procedure. The micro-thin Panther design further enhances maneuverability by enabling smooth navigation through restricted surgical corridors commonly encountered during microscope-assisted and minimally invasive cervical spine surgery.
Manufactured from premium medical-grade surgical stainless steel, the Neurosurgery Surgical Kerrison Rongeur, Micro Thin, 7″ (175 mm), 1.5 mm, 40° Up, Cervical Use Only, Panther offers exceptional corrosion resistance, mechanical strength, and dependable long-term performance. Precision manufacturing ensures consistently sharp cutting edges and precise jaw alignment through repeated surgical use and sterilization cycles. The corrosion-resistant stainless steel construction withstands frequent autoclaving while maintaining structural integrity, making the instrument a reliable reusable solution for hospitals, neurosurgical departments, spine centres, and specialised surgical facilities.
The advanced Panther design is engineered to enhance cutting efficiency, instrument responsiveness, and surgical precision. Precision-ground cutting jaws produce clean, controlled bone excision while minimizing crushing of surrounding tissue. This refined cutting action supports atraumatic surgical techniques, contributes to efficient spinal decompression, and promotes improved procedural outcomes. The compact 175 mm length provides excellent balance and maneuverability, allowing surgeons to maintain complete control during intricate cervical procedures.
Ergonomic spring handles provide a secure grip and superior tactile feedback throughout every stage of surgery. The smooth spring-loaded mechanism delivers consistent cutting performance with minimal operating force, reducing hand fatigue during lengthy microsurgical procedures while ensuring precise instrument control. Balanced weight distribution further enhances stability and responsiveness within confined cervical operative fields.
A satin matte finish minimizes glare under operating room lighting, improving visibility during delicate microscope-assisted procedures. Smooth external surfaces facilitate efficient cleaning and decontamination while supporting modern infection-control standards. Fully autoclavable, the instrument is designed to withstand repeated sterilization without compromising cutting performance, jaw alignment, or mechanical reliability.
Trusted by neurosurgeons and orthopedic spine surgeons worldwide, the Neurosurgery Surgical Kerrison Rongeur, Micro Thin, 7″ (175 mm), 1.5 mm, 40° Up, Cervical Use Only, Panther combines precision engineering, ergonomic comfort, and exceptional durability. It remains an indispensable instrument for cervical spinal decompression procedures where surgical precision, patient safety, and dependable clinical performance are paramount.
Key Features
- Specifically designed for cervical spine microsurgery
- Panther micro-thin design enhances precision and maneuverability
- 1.5mm bite enables ultra-precise bone and ligament removal
- 40° upward-angled jaw improves visualization and surgical access
- 7″ (175 mm) overall length provides excellent balance and control
- Manufactured from premium medical-grade surgical stainless steel
- Precision-ground cutting jaws ensure clean and accurate bone excision
- Ergonomic spring handle provides superior comfort and tactile feedback
- Smooth spring-loaded mechanism minimizes hand fatigue during extended procedures
- Satin matte finish reduces glare under operating room lighting
- Fully autoclavable and reusable for repeated professional use
- Corrosion-resistant construction ensures exceptional long-term durability
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Neurosurgery Surgical Kerrison Rongeur, Micro Thin, 7″ (175 mm), 1.5 mm, 40° Up, Cervical Use Only, Panther |
| Instrument Type | Micro Thin Kerrison Rongeur |
| Specialty | Neurosurgery / Cervical Spine Surgery |
| Overall Length | 7″ (175 mm) |
| Bite Size | 1.5 mm |
| Jaw Angle | 40° Up |
| Design | Panther Micro Thin |
| Intended Use | Cervical Spine Surgery Only |
| Material | Medical-Grade Surgical Stainless Steel |
| Handle Type | Ergonomic Spring Handle |
| Finish | Satin / Matte Finish |
| Sterilization | Fully Autoclavable |
| Reusable | Yes |
| Corrosion Resistant | Yes |
| Application | Precision Bone and Ligament Removal During Cervical Spinal Decompression Procedures |
FAQs
1. What is the Neurosurgery Surgical Kerrison Rongeur, Micro Thin, 7″ (175 mm), 1.5 mm, 40° Up, Cervical Use Only, Panther used for?
It is designed for precise removal of bone and ligament tissue during cervical laminectomy, laminotomy, foraminotomy, spinal decompression, microdiscectomy, and other cervical microsurgical procedures.
2. What are the advantages of the 1.5mm bite?
The 1.5mm bite provides ultra-fine cutting precision, allowing surgeons to remove very small sections of bone and ligament while protecting delicate neural structures.
3. Why is the Panther micro-thin design beneficial?
The Panther micro-thin profile improves maneuverability within narrow cervical operative fields, enhances instrument responsiveness, and supports microscope-assisted and minimally invasive spinal surgery.
4. What is the benefit of the 40° upward-angled jaw?
The 40° upward-angled jaw provides improved access and visibility in difficult anatomical regions, enabling precise bone removal with reduced instrument repositioning.
5. Is this Kerrison Rongeur reusable?
Yes. It is manufactured from premium medical-grade surgical stainless steel, fully autoclavable, and designed for repeated professional surgical use.
6. Which surgical specialties commonly use this instrument?
This instrument is primarily used by neurosurgeons and orthopedic spine surgeons performing cervical laminectomy, laminotomy, foraminotomy, spinal decompression, microdiscectomy, and other advanced cervical spine microsurgical procedures.

Reviews
There are no reviews yet.