The Micro Kerrison Rongeur 8″ 3mm 90° Up Panther is a precision-engineered surgical instrument designed for neurosurgeons and spine specialists who require exceptional accuracy during delicate bone removal procedures. This advanced micro Kerrison rongeur combines a specialized right-angle jaw configuration, ergonomic construction, and durable Panther surface finish to provide dependable performance in demanding surgical environments.
With an overall length of 8 inches (200mm), this Kerrison Rongeur offers an excellent balance of reach, control, and maneuverability. The compact micro design allows surgeons to perform precise movements within confined anatomical spaces while maintaining clear visualization of the surgical field. Its carefully balanced structure supports controlled handling during complex neurosurgical and spinal procedures.
The 3mm jaw size is designed for fine and controlled bone removal, making it ideal for microsurgical applications where precision is critical. The smaller bite capacity allows surgeons to remove small bone fragments with accuracy while reducing unnecessary manipulation of surrounding tissues. The precision-machined jaws provide consistent cutting action and dependable performance throughout surgical procedures.
The 90° upward angled jaw design provides a right-angle approach that improves access to challenging surgical locations. This configuration allows surgeons to work effectively around complex anatomical structures while maintaining an optimized viewing angle. The upward-facing tip is particularly useful in procedures where direct access and controlled instrument positioning are required.
Manufactured from premium surgical-grade stainless steel, the Neurosurgery Surgical Kerrison Rongeur provides excellent strength, corrosion resistance, and long-term durability. The Panther finish enhances the instrument’s surface protection while supporting smooth handling and reliable performance through repeated clinical use. This durable coating helps maintain the instrument’s professional appearance and resistance to wear during cleaning and sterilization cycles.
This Micro Kerrison Rongeur is commonly used in neurosurgery, spinal surgery, and orthopedic spine procedures requiring precise bone removal. It is suitable for applications including spinal decompression, laminectomy, laminotomy, and removal of small bone sections during advanced surgical interventions. The combination of a 3mm bite size and 90° upward angle makes it a valuable instrument for detailed surgical work requiring accuracy and control.
The ergonomic handle design supports comfortable operation during lengthy procedures. Its balanced construction allows smooth opening and closing movements while helping reduce hand fatigue. Surgeons can maintain precise control and consistent performance throughout delicate surgical tasks.
Designed for reusable professional use, the Panther Micro Kerrison Rongeur is compatible with standard hospital cleaning and sterilization procedures. Proper maintenance, inspection, and sterilization help preserve jaw alignment, mechanical function, and overall instrument longevity.
The Neurosurgery Surgical Kerrison Rongeur, Micro, 8″ (200mm) 3mm, 90° Up — Panther combines advanced surgical design, durable materials, and precision engineering to meet the requirements of modern neurosurgical and spinal procedures. It is an essential instrument for healthcare professionals seeking reliable performance, excellent access, and controlled bone removal capabilities.
Key Features
- Micro Kerrison Rongeur designed for neurosurgery and spinal applications
- 8″ (200mm) length provides excellent surgical reach and control
- 3mm jaw size enables precise removal of small bone sections
- 90° upward angled jaw improves access to difficult surgical areas
- Panther finish enhances durability and surface protection
- Manufactured from high-quality surgical-grade stainless steel
- Precision-machined jaws provide consistent cutting performance
- Micro design supports delicate microsurgical procedures
- Ergonomic handle improves surgeon comfort and handling accuracy
- Suitable for laminectomy, laminotomy, and spinal decompression procedures
- Reusable construction supports standard sterilization protocols
- Designed for reliable performance in professional operating rooms
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Neurosurgery Surgical Kerrison Rongeur, Micro, 8″ (200mm) 3mm, 90° Up — Panther |
| Instrument Type | Micro Kerrison Rongeur |
| Specialty | Neurosurgery / Spine Surgery |
| Overall Length | 8″ (200mm) |
| Jaw Size | 3mm |
| Jaw Direction | 90° Up |
| Finish | Panther Finish |
| Material | Surgical Grade Stainless Steel |
| Application | Precision bone and tissue removal |
| Design | Micro right-angle angled jaw design |
| Usage | Reusable surgical instrument |
| Sterilization | Compatible with standard surgical sterilization methods |
FAQs
1. What is a Micro Kerrison Rongeur used for?
A Micro Kerrison Rongeur is used for precise bone and tissue removal during neurosurgical and spinal procedures requiring controlled surgical access.
2. What is the advantage of a 90° Up Kerrison Rongeur?
The 90° upward angled jaw provides improved access to difficult surgical areas while allowing surgeons to maintain precise control.
3. Why is a 3mm bite size suitable for neurosurgery?
A 3mm bite size allows fine and controlled bone removal, making it ideal for delicate microsurgical procedures.
4. What is the Panther finish on this Kerrison Rongeur?
The Panther finish is a durable surface treatment designed to enhance instrument protection, handling, and long-term performance.
5. Is this Micro Kerrison Rongeur reusable?
Yes, this surgical instrument is designed for repeated use and can be processed through standard hospital cleaning and sterilization procedures.
6. Which procedures commonly use a 90° Up Kerrison Rongeur?
It is commonly used in spinal decompression, laminectomy, laminotomy, and other neurosurgical procedures requiring precise bone removal from challenging angles.

Reviews
There are no reviews yet.