The Cloward Style Blade Retractor 13mm x 75mm 7½″ is a premium-quality surgical instrument specifically engineered to provide precise and reliable soft tissue retraction during neurosurgical and cervical spinal procedures. Designed for use in anterior cervical approaches and other delicate spinal operations, this retractor delivers excellent exposure of the operative field while protecting surrounding muscles, fascia, and neurovascular structures. Its streamlined No Lip blade configuration allows surgeons to work with minimal obstruction, making it particularly valuable during microsurgical and minimally invasive procedures.
Achieving clear visualization is essential during cervical spine surgery and neurosurgical interventions. The Cloward Style Blade Retractor features a 13 mm wide by 75 mm long blade that provides controlled retraction of soft tissues while maintaining a stable surgical corridor. The absence of a retaining lip allows greater freedom for surgical instruments, implants, and visualization equipment to access the operative site without interference. This design is especially beneficial when precise instrument placement and unrestricted access are required.
With an overall length of 7½ inches, the Neurosurgery Surgical Cloward Style Blade Retractor 13mm x 75mm Blade, 7½″, No Lip offers an ideal balance between reach and maneuverability. Its compact profile enables surgeons to position the instrument accurately in confined surgical spaces while maintaining comfortable control throughout the procedure. The balanced construction also allows quick adjustments without disrupting tissue retraction or the sterile surgical field.
This Cloward Style Blade Retractor is commonly used during anterior cervical discectomy and fusion (ACDF), cervical decompression, spinal fusion, cervical disc replacement, vertebral procedures, neurosurgical exposure, and other spinal operations requiring precise tissue management. It is frequently incorporated into cervical retractor systems and spine surgery instrument sets because of its dependable performance and compatibility with advanced surgical techniques.
Manufactured from premium surgical-grade stainless steel, the instrument offers exceptional durability, corrosion resistance, and long-lasting clinical reliability. The precision-machined construction maintains blade alignment and structural integrity under continuous retraction forces. Its satin finish reduces glare from operating room lighting, allowing surgeons to maintain optimal visibility throughout microscopic and magnified procedures.
The smooth blade edges are carefully polished to promote atraumatic tissue handling while minimizing unnecessary pressure on surrounding structures. The No Lip blade design is particularly advantageous for surgeons who require unrestricted access during delicate spinal procedures, facilitating easier manipulation of surgical instruments and implants within the operative field.
The ergonomic handle provides a secure and comfortable grip, enabling precise placement, adjustment, and removal with minimal hand fatigue. The lightweight yet robust construction supports prolonged surgical procedures while maintaining consistent control and dependable retraction.
Designed for repeated professional use, the Neurosurgery Surgical Cloward Style Blade Retractor 13mm x 75mm Blade, 7½″, No Lip is fully reusable and compatible with standard hospital sterilization protocols, including steam autoclaving. Its high-quality stainless steel construction resists corrosion, staining, and wear through repeated sterilization cycles, making it a dependable long-term investment for hospitals, surgical centers, and specialty spine clinics.
Combining precision engineering, ergonomic handling, and durable construction, the Neurosurgery Surgical Cloward Style Blade Retractor 13mm x 75mm Blade, 7½″, No Lip remains a trusted instrument for surgeons seeking consistent tissue retraction, improved visualization, and reliable performance during complex neurosurgical and cervical spine procedures.
Key Features
- Precision Cloward Style Blade Retractor for cervical spine and neurosurgery
- Overall length of 7½″ (19 cm) for excellent surgical control
- 13 mm × 75 mm blade provides precise soft tissue retraction
- No Lip blade design offers unobstructed access to the operative site
- Ideal for ACDF, cervical decompression, spinal fusion, and neurosurgical procedures
- Smooth atraumatic blade helps protect surrounding soft tissues
- Manufactured from premium surgical-grade stainless steel
- Satin finish minimizes glare under operating room lighting
- Ergonomic handle ensures secure grip and precise manipulation
- Corrosion-resistant construction for long-term durability
- Fully reusable and compatible with steam autoclave sterilization
- Suitable for hospitals, spine centers, and neurosurgical operating rooms
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Neurosurgery Surgical Cloward Style Blade Retractor 13mm × 75mm Blade, 7½″, No Lip |
| Instrument Type | Hand-Held Blade Retractor |
| Specialty | Neurosurgery |
| Surgical Applications | ACDF, Cervical Spine Surgery, Spinal Fusion, Cervical Decompression, Neurosurgery |
| Overall Length | 7½″ (19 cm) |
| Blade Size | 13 mm × 75 mm |
| Blade Style | Cloward Style |
| Blade Configuration | No Lip |
| Tip Style | Smooth / Atraumatic |
| Material | Premium Surgical Grade Stainless Steel |
| Finish | Satin / Matte Finish |
| Reusable | Yes |
| Sterilization | Fully Autoclavable |
| Corrosion Resistant | Yes |
| Latex Free | Yes |
FAQs
1. What is the Neurosurgery Surgical Cloward Style Blade Retractor 13mm × 75mm Blade, 7½″, No Lip used for?
It is used to retract soft tissues during cervical spine and neurosurgical procedures, providing clear visualization and safe access to the operative site.
2. What is the advantage of the No Lip blade design?
The No Lip configuration provides unobstructed access to the surgical field, allowing easier instrument manipulation and implant placement during spinal procedures.
3. Which procedures commonly use this Cloward Style Retractor?
It is commonly used for anterior cervical discectomy and fusion (ACDF), cervical decompression, spinal fusion, cervical disc replacement, and other neurosurgical procedures.
4. What material is the instrument made from?
The retractor is manufactured from premium surgical-grade stainless steel, ensuring exceptional durability, corrosion resistance, and long-term performance.
5. Can this Cloward Style Blade Retractor be sterilized and reused?
Yes. The instrument is fully reusable and designed to withstand repeated steam autoclave sterilization while maintaining its precision, strength, and surgical reliability.

Reviews
There are no reviews yet.