The MIS Penfield Dissector Pull 10 5/8″ #4 4mm Curved Down Panther is a specialized minimally invasive neurosurgical instrument designed for controlled blunt dissection and precise tissue plane separation in deep spinal and cranial procedures. Engineered for MIS (Minimally Invasive Surgery) applications, it combines extended reach with a larger 4mm curved-down tip for enhanced efficiency in deeper or more resistant tissue planes.
The instrument features a 4mm curved-down Penfield-style tip designed for gentle but effective separation of soft tissue structures. The increased tip size provides greater surface contact for more efficient tissue plane development, while still maintaining atraumatic handling. The curved-down configuration allows the surgeon to follow anatomical planes naturally and improve access in deep or restricted surgical corridors.
The 10 5/8″ shaft provides extended reach required for minimally invasive spinal procedures, allowing surgeons to operate through smaller incisions while maintaining precise control at depth. This length is particularly useful in deep operative fields where stability and reach are critical.
The “Pull” design supports controlled traction during dissection, enabling the surgeon to gently develop tissue planes while maintaining stability and directional control. This feature is especially valuable in MIS spine surgery, where careful tissue separation is essential for safe exposure of neural structures.
The Panther ergonomic handle provides a secure, comfortable grip with excellent tactile feedback. Its balanced design reduces hand fatigue during prolonged procedures and enhances precision during fine microsurgical manipulation.
Manufactured from premium surgical-grade stainless steel, the instrument offers excellent durability, corrosion resistance, and long-term performance. It is fully autoclavable and designed to maintain structural integrity and tip accuracy through repeated sterilization cycles. The satin anti-glare finish improves visualization under operating room lighting by reducing reflections.
The MIS Penfield Dissector Pull 10 5/8″ #4 4mm Curved Down Panther is widely used in neurosurgery, spinal surgery, and minimally invasive spine procedures. It is particularly valuable for microdiscectomy, laminectomy, nerve root exposure, and deep tissue plane development in complex or constrained surgical environments.
Key Features
- 4mm curved-down Penfield-style tip for efficient dissection
- 10 5/8″ extended shaft for deep MIS access
- Designed for minimally invasive spinal surgery
- “Pull” configuration for controlled tissue plane development
- Panther ergonomic handle for improved grip and comfort
- Enhanced surface contact for efficient blunt dissection
- Atraumatic design minimizes tissue trauma
- Fully autoclavable and reusable
- Satin anti-glare finish improves surgical visibility
- Suitable for neurosurgery and spinal MIS procedures
Product Specifications Table
| Specification | Details |
|---|---|
| Product Name | MIS Penfield Dissector Pull 10 5/8″ #4 4mm Curved Down Panther |
| Material | Surgical Grade Stainless Steel |
| Instrument Type | MIS Neurosurgical Dissector |
| Tip Size | 4mm |
| Tip Design | Curved Down Penfield Style |
| Length | 10 5/8 inches |
| Handle | Panther ergonomic handle |
| Usage | Blunt dissection, tissue separation, MIS spinal procedures |
| Reusability | Reusable |
| Sterilization | Autoclavable |
| Finish | Satin / Matte (Anti-Glare) |
| Application | Neurosurgery, spinal surgery, minimally invasive spine surgery |
FAQs
1. What is the MIS Penfield Dissector Pull used for?
It is used for controlled blunt dissection and tissue plane development in minimally invasive spinal and neurosurgical procedures.
2. What is the advantage of the 4mm tip?
The 4mm tip provides increased surface contact for more efficient tissue separation.
3. Why is the curved-down design important?
It improves access and control in deep or narrow surgical corridors.
4. What does the “Pull” design do?
It allows controlled traction to gently develop tissue planes during dissection.
5. Which procedures use this instrument?
It is commonly used in microdiscectomy, laminectomy, and other MIS spinal procedures.

Reviews
There are no reviews yet.