The Distal Tibia Locking Plates 4 12 Holes SS 316L is a versatile orthopedic implant system designed for internal fixation of selected fractures involving the distal tibia. The system combines multiple plate configurations, left- and right-sided anatomical options, and compatible LCP screws to provide orthopedic surgical teams with a broad range of fixation components for different fracture patterns and patient anatomies.
Distal tibia fractures can vary significantly in location, morphology, displacement, comminution, bone quality, and soft-tissue involvement. A selection of different plate lengths allows the surgeon to choose an implant configuration according to the patient’s anatomy and the planned fixation strategy. This system includes 4-hole, 6-hole, 8-hole, 10-hole, and 12-hole plates, providing multiple options for plate length and fixation-point distribution.
The availability of left (L) and right (R) plates provides side-specific configurations for the corresponding distal tibia. Anatomical compatibility is an important consideration when selecting a fixation plate. The appropriate implant should be determined using patient-specific anatomy, fracture morphology, imaging, bone quality, surgical approach, and the manufacturer’s approved indications.
The system incorporates LCP screws, forming a locking plate and screw fixation construct. LCP, or Locking Compression Plate, technology uses compatible screws that engage with locking interfaces incorporated into the plate. When correctly assembled, compatible locking screws establish a fixed-angle relationship between the screw and plate. The exact fixation options and technique depend on the specific implant design and should be determined using the manufacturer’s surgical technique.
The 4–12 hole range provides several plate-length options. Shorter plates can offer a more compact fixation configuration when appropriate, while longer plates provide additional fixation points and plate coverage when clinically required. The number of holes should not be used as the sole basis for implant selection. Fracture characteristics, bone stock, reduction requirements, soft-tissue considerations, and the surgeon’s fixation strategy should all be evaluated.
Manufactured from SS 316L stainless steel, the plates provide a material platform widely used in medical and surgical applications. SS 316L is a low-carbon stainless-steel alloy recognized for corrosion resistance and suitable material properties for various surgical environments. The performance of an orthopedic implant depends on the complete implant design, dimensions, manufacturing process, surface finish, and intended clinical application.
The 102-piece system provides a substantial selection of distal tibia plates and compatible LCP screws within one organized set. This configuration can support orthopedic trauma departments, hospitals, surgical centers, and specialized orthopedic facilities that require multiple plate options readily available for different surgical cases. A consolidated system can also assist with surgical preparation and orthopedic implant inventory management.
Distal tibia fixation requires careful planning because of the complex anatomy and surrounding soft-tissue structures. The surgeon should determine the appropriate plate configuration and surgical approach based on the patient’s individual anatomy and fracture characteristics. Accurate fracture reduction, appropriate implant positioning, compatible screw selection, and proper fixation technique are essential aspects of the surgical procedure.
Before implantation, each plate and screw should be carefully inspected for damage, deformation, corrosion, contamination, compromised threads, or other abnormalities. Particular care should be taken to protect the locking interfaces and screw threads during handling. Only compatible plates, screws, and approved instrumentation should be used together.
Cleaning and sterilization must be performed according to the manufacturer’s validated instructions for use (IFU). While SS 316L is commonly used in surgical environments and can be processed using validated sterilization methods, the material specification itself does not define a universal sterilization cycle. Healthcare facilities should follow the manufacturer’s validated processing parameters and applicable infection-control requirements.
With 4, 6, 8, 10 and 12-hole configurations, bilateral left- and right-sided designs, compatible LCP screws, and SS 316L construction, this Distal Tibia Locking Plate System offers orthopedic professionals a versatile selection of fixation components for selected distal tibia fracture procedures.
Key Features
- Distal tibia locking plate system designed for selected orthopedic fracture fixation applications.
- Available in 4, 6, 8, 10 and 12-hole configurations.
- Includes left (L) and right (R) anatomical plate options.
- Supplied with compatible LCP locking screws.
- Manufactured from SS 316L stainless steel.
- Multiple plate lengths provide flexibility for different fixation requirements.
- Locking screw interfaces support fixed-angle plate-and-screw fixation when compatible components are properly assembled.
- 102-piece system provides an extensive selection of plates and screws.
- Designed for selected distal tibia and orthopedic trauma procedures.
- Bilateral configurations accommodate left- and right-sided anatomy.
- Suitable for professional use by qualified orthopedic surgeons and trained surgical teams.
- Supports organized orthopedic implant inventory and surgical preparation.
- Components should be inspected for integrity and compatibility before implantation.
- Cleaning and sterilization should follow the manufacturer’s validated instructions.
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Distal Tibia Locking Plates |
| Anatomical Site | Distal Tibia |
| Plate Type | Locking Distal Tibia Plate |
| Hole Configurations | 4, 6, 8, 10 & 12 Holes |
| Laterality | Left (L) & Right (R) |
| Screw Type | LCP Screws |
| Total System Quantity | 102 Pieces |
| Material | SS 316L Stainless Steel |
| Fixation Technology | Locking Plate and Screw System |
| Primary Application | Distal Tibia Fracture Fixation |
| Surgical Specialty | Orthopedic Surgery / Orthopedic Trauma |
| Plate Options | Multiple Length Configurations |
| Intended Users | Qualified Orthopedic Professionals |
| Sterilization | Follow manufacturer’s validated sterilization instructions |
| Component Compatibility | Use specified compatible plates, screws and instrumentation |
| Implant Selection | Based on patient anatomy, fracture pattern and surgeon assessment |
FAQs
1. What are distal tibia locking plates used for?
Distal tibia locking plates are orthopedic fixation implants used for stabilization of selected distal tibia fractures. The appropriate plate depends on the patient’s anatomy, fracture morphology, bone quality, surgical approach, and fixation strategy.
2. What hole sizes are included in this distal tibia plate system?
This system includes 4-hole, 6-hole, 8-hole, 10-hole, and 12-hole configurations, providing multiple options for plate length and fixation-point distribution.
3. Are both left and right distal tibia plates included?
Yes. The system is specified with left and right configurations, allowing selection of the appropriate side-specific plate for the affected limb.
4. Are LCP screws supplied with the plates?
Yes. The product title specifies that the system includes LCP screws. Exact screw sizes and quantities should be confirmed against the manufacturer’s component list.
5. What does LCP mean in orthopedic fixation?
LCP stands for Locking Compression Plate. LCP technology incorporates locking interfaces that allow compatible screws to engage with the plate and create a fixed-angle relationship when assembled according to the manufacturer’s specifications.
6. What material are these distal tibia plates made from?
The plates are specified as SS 316L stainless steel, a low-carbon stainless-steel alloy commonly used in medical and surgical applications due to its corrosion-resistant characteristics.

Reviews
There are no reviews yet.