The 11.8 cm Safe Jaw Femoral Popliteal Clamp Cardiovascular Clamp is a specialized vascular surgical instrument engineered to provide safe, reliable, and atraumatic occlusion of the femoral and popliteal arteries during cardiovascular and peripheral vascular procedures. Designed for precision and tissue preservation, this clamp enables surgeons to temporarily interrupt blood flow while minimizing trauma to vessel walls. It is an essential instrument for vascular surgeons performing arterial reconstruction, bypass grafting, endarterectomy, and other procedures requiring controlled vascular occlusion.
With an overall length of 11.8 cm (approximately 4.6 inches), this clamp is compact enough to provide excellent maneuverability in confined surgical fields while offering precise control during delicate vascular interventions. Its balanced design allows surgeons to position the clamp accurately around femoral and popliteal vessels without obstructing the operative field, making it particularly valuable during lower extremity vascular surgery.
A defining feature of the 11.8 cm Safe Jaw Femoral Popliteal Clamp Cardiovascular Clamp is its advanced Safe Jaw technology. The atraumatic jaws are engineered to distribute clamping pressure evenly across the vessel, reducing the likelihood of endothelial injury and unnecessary compression. This controlled occlusion helps preserve vessel integrity while providing dependable interruption of blood flow, an important consideration during complex vascular reconstructions and bypass procedures.
Manufactured from premium surgical-grade stainless steel, the clamp offers exceptional durability, corrosion resistance, and dependable long-term performance. Precision manufacturing ensures smooth jaw alignment and consistent clamping action throughout repeated surgical use. The satin finish minimizes glare under operating room lighting while simplifying cleaning and maintenance after each procedure.
The instrument incorporates a precision box lock and secure ratchet mechanism that allow surgeons to apply consistent clamping pressure with confidence. This reliable locking system maintains stable vessel occlusion without excessive force, reducing the risk of tissue trauma. Ergonomically designed finger ring handles provide excellent grip, balance, and tactile feedback, helping minimize hand fatigue during prolonged vascular procedures.
The 11.8 cm Safe Jaw Femoral Popliteal Clamp Cardiovascular Clamp is widely used during femoral-popliteal bypass surgery, peripheral arterial reconstruction, vascular graft placement, thrombectomy, endarterectomy, aneurysm repair, and other lower extremity vascular interventions. Its atraumatic design also makes it suitable for procedures requiring temporary control of medium-sized peripheral arteries where vessel preservation is critical.
Designed for repeated professional use, the clamp is fully reusable and compatible with standard hospital sterilization methods, including steam autoclaving. Its high-quality stainless steel construction maintains structural integrity, jaw alignment, and mechanical performance through repeated cleaning and sterilization cycles, ensuring dependable long-term service in busy operating rooms.
Whether used in vascular surgery departments, cardiovascular operating rooms, or specialized surgical centers, the 11.8 cm Safe Jaw Femoral Popliteal Clamp Cardiovascular Clamp delivers precise vessel control, atraumatic performance, and outstanding durability. Combining advanced Safe Jaw technology, ergonomic handling, and premium materials, this instrument is an excellent choice for surgeons seeking reliable performance during complex vascular procedures.
Key Features
- Precision 11.8 cm Safe Jaw Femoral Popliteal Clamp Cardiovascular Clamp
- Safe Jaw technology minimizes vascular tissue trauma
- Designed for temporary occlusion of femoral and popliteal arteries
- Ideal for cardiovascular and peripheral vascular surgery
- Atraumatic jaws provide secure and controlled vessel clamping
- Premium surgical-grade stainless steel construction
- Precision box lock for smooth jaw alignment
- Secure ratchet mechanism ensures dependable clamping pressure
- Ergonomic finger ring handles improve comfort and control
- Satin finish reduces glare in the operating room
- Fully reusable and steam autoclavable
- Corrosion-resistant construction for long-lasting performance
Product Specifications
| Specification | Details |
|---|---|
| Product Name | 11.8 cm Safe Jaw Femoral Popliteal Clamp Cardiovascular Clamp |
| Instrument Type | Femoral Popliteal Vascular Clamp |
| Overall Length | 11.8 cm (Approx. 4.6″) |
| Jaw Type | Safe Jaw Atraumatic Vascular Jaws |
| Jaw Style | Straight |
| Locking Mechanism | Box Lock with Ratchet |
| Material | Premium Surgical Grade Stainless Steel |
| Finish | Satin/Matte Finish |
| Reusable | Yes |
| Sterilization | Steam Autoclave Compatible |
| Specialty | Cardiovascular & Peripheral Vascular Surgery |
| Applications | Femoral-Popliteal Bypass, Endarterectomy, Arterial Reconstruction, Vascular Grafting, Peripheral Vascular Procedures |
FAQs
1. What is the 11.8 cm Safe Jaw Femoral Popliteal Clamp Cardiovascular Clamp used for?
It is used for temporary occlusion of the femoral and popliteal arteries during vascular reconstruction, bypass surgery, endarterectomy, and other peripheral vascular procedures.
2. What is the advantage of the Safe Jaw design?
The Safe Jaw design distributes pressure evenly across the vessel, reducing tissue trauma and helping preserve the integrity of delicate vascular structures during temporary occlusion.
3. Is this clamp suitable for femoral-popliteal bypass surgery?
Yes. It is specifically designed for femoral-popliteal bypass procedures and other lower extremity vascular surgeries that require precise and atraumatic vessel control.
4. What material is the Safe Jaw Femoral Popliteal Clamp made from?
The clamp is manufactured from premium surgical-grade stainless steel, offering excellent corrosion resistance, strength, and long-term durability.
5. Can the 11.8 cm Safe Jaw Femoral Popliteal Clamp Cardiovascular Clamp be sterilized and reused?
Yes. The instrument is fully reusable and compatible with standard steam autoclave sterilization, maintaining its precision, performance, and structural integrity after repeated sterilization cycles.

Reviews
There are no reviews yet.