The 12 1/2″ Cherry Supraceliac Clamp 2×3 Cardiovascular Clamp is a highly specialized cardiovascular surgical instrument engineered for precise occlusion and control of the supraceliac aorta and major vascular structures. Designed for advanced vascular and cardiovascular procedures, this clamp provides surgeons with reliable performance during complex operations requiring temporary interruption of blood flow. Its Cherry pattern design, extended length, and specialized jaw configuration make it an essential instrument for aortic surgery and vascular reconstruction.
With an overall length of 12 1/2 inches (approximately 31.8 cm), this supraceliac clamp provides the extended reach required for deep abdominal and vascular surgical fields. The long shaft design allows surgeons to access difficult anatomical locations while maintaining a comfortable working position and excellent instrument control. This makes it particularly valuable during procedures involving the abdominal aorta and other large vascular structures.
The Cherry Supraceliac Clamp 2×3 Cardiovascular Clamp features a specialized 2×3 jaw configuration designed to provide secure and controlled vessel engagement. The jaw pattern allows effective gripping of vascular tissue while distributing pressure evenly to reduce unnecessary trauma. This controlled clamping capability is essential during supraceliac aortic procedures where maintaining vessel integrity and achieving reliable occlusion are critical.
The atraumatic jaw design supports safe handling of delicate vascular structures by minimizing excessive compression and reducing the risk of tissue injury. This makes the clamp suitable for complex procedures such as aortic aneurysm repair, vascular graft placement, abdominal vascular reconstruction, and other major cardiovascular interventions requiring temporary vessel control.
Manufactured from premium surgical-grade stainless steel, the 12 1/2″ Cherry Supraceliac Clamp provides exceptional durability, corrosion resistance, and long-term reliability. Precision engineering ensures accurate jaw alignment, smooth mechanical operation, and consistent performance after repeated surgical use. The satin finish reduces glare from operating room lights while providing a smooth surface that supports efficient cleaning and sterilization.
The instrument is designed with a precision box lock and secure ratchet mechanism that allow surgeons to apply controlled pressure during vascular procedures. This reliable locking system maintains stable vessel occlusion while providing excellent tactile feedback. The ergonomic handle design enhances comfort, balance, and maneuverability, helping surgeons maintain precise control during lengthy and demanding operations.
The 12 1/2″ Cherry Supraceliac Clamp 2×3 Cardiovascular Clamp is commonly used in vascular surgery, aortic aneurysm repair, abdominal aortic procedures, supraceliac aortic occlusion, vascular reconstruction, and complex cardiovascular operations. Its extended reach and specialized jaw design make it a valuable addition to surgical instrument sets used by vascular surgeons, cardiovascular specialists, and advanced surgical teams.
Designed for repeated professional use, this reusable vascular clamp is compatible with standard hospital sterilization procedures, including steam autoclaving. The high-quality stainless steel construction maintains its structural integrity, jaw precision, and mechanical reliability through repeated cleaning and sterilization cycles.
The 12 1/2″ Cherry Supraceliac Clamp 2×3 Cardiovascular Clamp combines specialized vascular design, durable construction, and precise surgical performance. Its ability to provide controlled supraceliac aortic occlusion makes it an important instrument for surgeons performing complex cardiovascular and vascular procedures requiring dependable vessel management.
Key Features
- Precision 12 1/2″ Cherry Supraceliac Clamp 2×3 Cardiovascular Clamp
- Designed for supraceliac aortic and major vessel occlusion
- Extended length provides access to deep surgical fields
- 2×3 jaw configuration offers secure vascular control
- Atraumatic jaw design helps minimize tissue injury
- Ideal for complex cardiovascular and vascular procedures
- Premium surgical-grade stainless steel construction
- Precision box lock ensures accurate jaw alignment
- Secure ratchet mechanism provides controlled pressure
- Ergonomic handle design improves surgical comfort
- Fully reusable and steam autoclavable
- Corrosion-resistant for long-lasting clinical performance
Product Specifications
| Specification | Details |
|---|---|
| Product Name | 12 1/2″ Cherry Supraceliac Clamp 2×3 Cardiovascular Clamp |
| Instrument Type | Supraceliac Aortic Vascular Clamp |
| Overall Length | 12 1/2″ (Approx. 31.8 cm) |
| Jaw Configuration | 2×3 Jaw |
| Jaw Type | Atraumatic Vascular Jaws |
| Clamping Style | Aortic Occlusion Clamp |
| Locking Mechanism | Box Lock with Ratchet |
| Material | Premium Surgical Grade Stainless Steel |
| Finish | Satin/Matte Finish |
| Reusable | Yes |
| Sterilization | Steam Autoclave Compatible |
| Specialty | Cardiovascular & Vascular Surgery |
| Applications | Supraceliac Aortic Clamping, Aortic Aneurysm Repair, Vascular Reconstruction, Abdominal Aortic Surgery |
FAQs
1. What is the 12 1/2″ Cherry Supraceliac Clamp used for?
It is used for temporary occlusion and control of the supraceliac aorta and major blood vessels during complex vascular and cardiovascular procedures.
2. What is the purpose of the 2×3 jaw design?
The 2×3 jaw configuration provides secure vessel engagement and controlled pressure distribution for reliable vascular occlusion during surgery.
3. Is this clamp suitable for aortic aneurysm repair?
Yes. The Cherry Supraceliac Clamp is commonly used in aortic aneurysm repair, vascular reconstruction, and other major aortic procedures.
4. What material is the Cherry Supraceliac Clamp made from?
The instrument is manufactured from premium surgical-grade stainless steel, offering excellent durability, corrosion resistance, and long-term reliability.
5. Can the 12 1/2″ Cherry Supraceliac Clamp 2×3 Cardiovascular Clamp be sterilized and reused?
Yes. The clamp is fully reusable and compatible with standard steam autoclave sterilization while maintaining its precision and performance after repeated use.