The 5″ Cooley Neonatal Vascular Clamp Spoon Jaw is a premium-quality surgical instrument engineered to provide precise, atraumatic vascular control during neonatal, pediatric, and cardiovascular procedures. Specifically designed for delicate vascular structures, this specialized clamp offers surgeons exceptional accuracy when temporary vessel occlusion is required without causing unnecessary trauma to fragile tissues. Its compact 5-inch length and spoon-shaped jaw configuration make it an indispensable instrument for procedures involving extremely small blood vessels where precision is critical.
Widely used in neonatal cardiovascular surgery, pediatric vascular reconstruction, congenital heart surgery, and microsurgical procedures, the Cooley Neonatal Vascular Clamp provides reliable vessel control while preserving the integrity of delicate vascular tissue. The carefully designed spoon jaws distribute clamping pressure evenly across the vessel, helping minimize localized trauma and reducing the risk of vessel damage during temporary occlusion. This atraumatic design supports improved surgical outcomes by allowing surgeons to maintain effective blood flow control while protecting sensitive anatomical structures.
Manufactured from premium surgical-grade stainless steel, the 5″ Cooley Neonatal Vascular Clamp Spoon Jaw delivers exceptional durability, corrosion resistance, and long-term performance. The high-quality material maintains its structural integrity through repeated sterilization cycles, ensuring dependable functionality in demanding operating room environments. Precision manufacturing guarantees smooth jaw alignment, consistent clamping pressure, and reliable mechanical performance throughout the instrument’s service life.
The ergonomic handle design provides excellent balance and tactile feedback, allowing surgeons to perform delicate maneuvers with confidence. Its lightweight construction minimizes hand fatigue during prolonged procedures while offering superior control in confined surgical fields. The compact overall length enhances maneuverability around intricate anatomical structures, making the instrument particularly valuable during neonatal and infant surgical procedures where operating space is limited.
The spoon jaw configuration offers a significant advantage during vascular anastomosis by providing broad yet gentle contact with blood vessels. This helps maintain vessel stability during suturing and reconstruction while reducing excessive compression that could compromise vascular tissue. Surgeons performing delicate arterial and venous repairs benefit from the instrument’s ability to provide secure temporary occlusion without sacrificing tissue preservation.
This Cooley neonatal vascular clamp is suitable for use in hospitals, pediatric specialty centers, cardiovascular operating rooms, and microsurgical practices. It is commonly selected by cardiovascular surgeons, pediatric surgeons, vascular surgeons, transplant specialists, and microsurgeons who require dependable performance during highly specialized procedures. Whether used for congenital heart defect correction, neonatal vascular repair, or complex reconstructive surgery, this instrument delivers the precision necessary for advanced surgical care.
The instrument is fully compatible with standard hospital cleaning and sterilization protocols, including steam autoclaving, allowing efficient reprocessing between procedures. With proper maintenance and routine inspection, the clamp retains its precision alignment and mechanical integrity for years of dependable clinical use.
Combining precision engineering, atraumatic spoon jaws, durable stainless steel construction, and ergonomic handling, the 5″ Cooley Neonatal Vascular Clamp Spoon Jaw is an essential addition to any professional vascular and cardiovascular surgical instrument set. It offers the reliability, safety, and performance demanded by modern neonatal and pediatric surgical practice.
Key Features
- 5″ Cooley Neonatal Vascular Clamp with precision spoon jaws
- Designed for neonatal, pediatric, and cardiovascular surgery
- Spoon-shaped jaws provide gentle, atraumatic vessel occlusion
- Ideal for delicate vascular anastomosis procedures
- Manufactured from premium surgical-grade stainless steel
- Precision jaw alignment for secure and consistent clamping
- Ergonomic handle improves comfort and surgical control
- Lightweight, balanced design enhances maneuverability
- Corrosion-resistant construction for long service life
- Compatible with standard autoclave sterilization methods
- Suitable for microsurgery, vascular reconstruction, and congenital heart procedures
- Reusable professional-grade surgical instrument
Product Specifications Table
| Product Specification | Details |
|---|---|
| Product Name | Cooley Neonatal Vascular Clamp Spoon Jaw |
| Overall Length | 5 inches |
| Instrument Type | Neonatal Vascular Clamp |
| Jaw Style | Spoon Jaw |
| Function | Temporary vascular occlusion |
| Surgical Applications | Neonatal, pediatric, cardiovascular, vascular, microsurgery |
| Material | Surgical-grade stainless steel |
| Handle Design | Ergonomic finger-ring handle |
| Finish | Satin/Matte surgical finish |
| Sterilization | Autoclavable and standard hospital sterilization compatible |
| Reusable | Yes |
| Specialty | Cardiovascular, Pediatric, Vascular Surgery |
FAQs
1. What is the 5″ Cooley Neonatal Vascular Clamp Spoon Jaw used for?
It is used for temporary occlusion of small blood vessels during neonatal, pediatric, cardiovascular, and microsurgical procedures requiring precise vascular control.
2. What is the advantage of a spoon jaw vascular clamp?
The spoon-shaped jaws distribute pressure evenly across delicate vessels, helping reduce tissue trauma while providing secure and stable vessel occlusion.
3. Is this clamp suitable for vascular anastomosis?
Yes. It is specifically designed to assist surgeons during vascular anastomosis by stabilizing blood vessels while protecting fragile tissue.
4. What material is this Cooley vascular clamp manufactured from?
The instrument is manufactured from premium surgical-grade stainless steel that offers excellent corrosion resistance, durability, and long-term performance.
5. Can the 5″ Cooley Neonatal Vascular Clamp Spoon Jaw be sterilized and reused?
Yes. It is fully reusable and compatible with standard hospital sterilization methods, including steam autoclaving, when properly cleaned and maintained.
6. Which surgical specialties commonly use this instrument?
The clamp is widely used in neonatal surgery, pediatric surgery, cardiovascular surgery, vascular surgery, congenital heart surgery, transplant procedures, and microsurgical vascular reconstruction.

Reviews
There are no reviews yet.