The Cardiovascular B Approximator Clamp Frame 1.0 2.25mm is a high-performance microvascular surgical instrument developed to provide precise vessel approximation and temporary vascular occlusion during cardiovascular, vascular, and reconstructive microsurgical procedures. Specifically engineered for blood vessels measuring 1.0mm to 2.25mm in diameter, this specialized clamp frame securely aligns vessel ends while creating a stable, bloodless operative field for delicate vascular anastomosis. Its precision engineering and atraumatic design make it an indispensable instrument for surgeons performing complex vascular reconstruction where stability and accuracy are essential.
Precise approximation of blood vessels is critical to achieving successful vascular anastomosis. The Cardiovascular B Approximator Clamp Frame 1.0–2.25mm is designed to securely hold both ends of the vessel in proper alignment throughout the suturing process. By minimizing vessel movement and maintaining temporary blood flow occlusion, the clamp frame allows surgeons to perform delicate microsutures with improved visibility and greater precision. This controlled stabilization helps reduce operative time while supporting consistent and reliable surgical outcomes.
Designed for vessels measuring 1.0mm to 2.25mm, the instrument features finely engineered atraumatic jaws that distribute clamping pressure evenly across the vessel wall. This balanced compression effectively interrupts blood flow while helping preserve endothelial integrity and minimizing the risk of intimal injury, vessel deformation, or unnecessary tissue trauma. The precision clamp mechanism provides dependable stabilization without excessive force, making it suitable for delicate arterial and venous reconstruction.
Manufactured from premium surgical-grade stainless steel, the Cardiovascular B Approximator Clamp Frame 1.0–2.25mm provides exceptional mechanical strength, corrosion resistance, and long-term clinical durability. Precision machining ensures smooth clamp operation, accurate jaw alignment, and reliable performance during repeated surgical use. The satin finish minimizes glare under operating room lighting while providing a smooth surface that facilitates efficient cleaning and maintenance.
The lightweight yet rigid frame offers excellent stability without obstructing the operative field. Its ergonomic design enhances surgeon comfort, tactile control, and precise instrument handling during prolonged procedures. The frame maintains accurate vessel positioning throughout vascular reconstruction, contributing to improved efficiency and consistent microsurgical performance.
The Cardiovascular B Approximator Clamp Frame 1.0–2.25mm is widely used in cardiovascular surgery, peripheral vascular surgery, microvascular reconstruction, plastic and reconstructive surgery, neurosurgery, hand surgery, transplant surgery, pediatric vascular surgery, and experimental microsurgery. It is particularly valuable for vascular anastomosis, arterial repair, bypass grafting, free flap surgery, vessel grafting, and reconstructive procedures requiring precise vessel alignment.
Fully reusable and compatible with standard hospital sterilization methods, including steam autoclaving, the instrument is designed to withstand repeated sterilization cycles without compromising structural integrity, jaw alignment, or functional performance. Its durable stainless steel construction provides dependable long-term value for hospitals, cardiovascular centers, and specialized microsurgical facilities.
Combining precision engineering, atraumatic vessel handling, and secure vessel approximation, the Cardiovascular B Approximator Clamp Frame 1.0–2.25mm meets the demanding standards of modern cardiovascular and microvascular surgery. It delivers the precision, durability, and reliability required for successful vascular reconstruction and advanced microsurgical procedures.
Key Features
- Precision Cardiovascular B Approximator Clamp Frame 1.0–2.25mm
- Designed for vessels measuring 1.0mm to 2.25mm
- Provides accurate vessel approximation during vascular anastomosis
- Atraumatic jaws minimize endothelial and tissue trauma
- Maintains secure temporary vessel occlusion and alignment
- Ideal for cardiovascular and microvascular surgery
- Suitable for arterial and venous reconstruction
- Manufactured from premium surgical-grade stainless steel
- Lightweight frame provides excellent stability and control
- Satin finish minimizes glare under surgical lighting
- Fully reusable and autoclavable
- Corrosion-resistant construction for long-term clinical durability
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Cardiovascular B Approximator Clamp Frame 1.0–2.25mm |
| Instrument Type | Microvascular Approximator Clamp Frame |
| Specialty | Cardiovascular & Microvascular Surgery |
| Vessel Size Compatibility | 1.0mm – 2.25mm |
| Clamp Style | B Approximator Frame |
| Jaw Type | Atraumatic |
| Function | Vessel Approximation & Temporary Occlusion |
| Material | Premium Surgical Grade Stainless Steel |
| Finish | Satin / Matte Finish |
| Reusable | Yes |
| Sterilization | Fully Autoclavable |
| Corrosion Resistant | Yes |
| Latex Free | Yes |
| Clinical Use | Cardiovascular, Microvascular, Peripheral Vascular, Plastic & Reconstructive, Neurosurgical, Hand, Transplant, and Pediatric Vascular Procedures |
FAQs
1. What is the Cardiovascular B Approximator Clamp Frame 1.0–2.25mm used for?
It is designed to temporarily occlude and accurately approximate blood vessels measuring 1.0mm to 2.25mm during cardiovascular and microvascular procedures, enabling precise vascular anastomosis and reconstruction.
2. What is the advantage of the B approximator clamp frame?
The B approximator frame securely aligns both vessel ends, minimizes movement during suturing, improves visualization, and supports accurate vascular reconstruction.
3. Are the jaws atraumatic?
Yes. The atraumatic jaws apply even pressure across the vessel wall to preserve endothelial integrity while minimizing vessel deformation, intimal injury, and surrounding tissue trauma.
4. Which surgical specialties commonly use this instrument?
The instrument is widely used in cardiovascular surgery, peripheral vascular surgery, microvascular reconstruction, plastic and reconstructive surgery, neurosurgery, hand surgery, transplant surgery, pediatric vascular surgery, and free flap reconstruction.
5. Is the Cardiovascular B Approximator Clamp Frame 1.0–2.25mm reusable?
Yes. It is fully reusable and compatible with standard steam autoclave sterilization, ensuring long-term precision, stability, and dependable clinical performance.
6. What material is used to manufacture the Cardiovascular B Approximator Clamp Frame 1.0–2.25mm?
The instrument is manufactured from premium surgical-grade stainless steel, providing excellent corrosion resistance, precise engineering, long-lasting durability, and reliable performance for professional surgical environments.

Reviews