Glassman Anterior Resection Clamp Tip 25mm Jaw Serrated 24.7cm General Surgery Instruments is a specialized surgical instrument designed for secure clamping and temporary occlusion of the bowel during anterior resection, colorectal surgery, gastrointestinal procedures, and intestinal anastomosis. Its precision-engineered serrated jaws provide a firm grip on bowel tissue while helping maintain tissue integrity throughout the surgical procedure.
Manufactured from premium surgical-grade stainless steel, the Glassman Anterior Resection Clamp offers exceptional durability, corrosion resistance, and long-term clinical reliability. The high-quality stainless steel construction maintains accurate jaw alignment and smooth mechanical performance through repeated cleaning and sterilization cycles. A satin or mirror-polished finish minimizes glare under operating room lighting while providing a smooth, easy-to-clean surface.
The instrument features a 25 mm serrated tip with precision jaws designed to securely grasp and stabilize intestinal tissue. The serration pattern provides reliable tissue retention while distributing clamping pressure evenly to reduce unnecessary tissue trauma during bowel resection and reconstruction.
Measuring 24.7 cm in overall length, the clamp provides excellent reach and maneuverability in deep pelvic and abdominal operative fields. Its balanced design enables precise placement and secure handling during complex colorectal procedures.
The integrated ratchet locking mechanism maintains consistent clamping pressure without continuous hand force, allowing dependable bowel occlusion and tissue stabilization throughout the operation.
Ergonomic finger ring handles provide a secure and comfortable grip, improving instrument control while reducing hand fatigue during lengthy surgical procedures. The balanced construction supports smooth, controlled manipulation in demanding operative environments.
Glassman Anterior Resection Clamp is widely used in colorectal surgery, gastrointestinal surgery, general surgery, and other abdominal procedures involving bowel resection, anterior resection, intestinal reconstruction, and anastomosis.
Designed for repeated professional use, the instrument is fully reusable and compatible with standard hospital sterilization methods, including steam autoclaving. Its premium stainless steel construction resists rust, corrosion, staining, and wear, ensuring dependable performance over years of clinical use.
Each instrument undergoes comprehensive quality control testing to verify jaw alignment, serration accuracy, ratchet engagement, and overall mechanical reliability before clinical use.
Key Features
- Premium surgical-grade stainless steel construction
- 25 mm precision serrated tip for secure tissue grip
- Designed for anterior resection and bowel surgery
- Provides temporary intestinal occlusion and stabilization
- 24.7 cm overall length for deep abdominal and pelvic access
- Precision serrated jaws minimize tissue slippage
- Ratchet locking mechanism for consistent clamping pressure
- Ergonomic finger ring handles for comfortable control
- Balanced design reduces hand fatigue
- Smooth mechanical operation with precise jaw alignment
- Corrosion, rust, and stain resistant
- Fully reusable and autoclavable
- Manufactured according to international quality standards
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Glassman Anterior Resection Clamp |
| Instrument Type | Anterior Resection Clamp |
| Specialty | General Surgery, Colorectal Surgery, Gastrointestinal Surgery |
| Overall Length | 24.7 cm |
| Tip Size | 25 mm |
| Jaw Type | Precision Serrated Jaws |
| Material | Premium Surgical Grade Stainless Steel |
| Finish | Satin / Mirror Finish |
| Locking Mechanism | Ratchet Lock |
| Handle Type | Finger Ring Handles |
| Sterility | Non-Sterile |
| Reusable | Yes |
| Autoclavable | Yes |
| Corrosion Resistant | Yes |
| Rust Resistant | Yes |
| Latex Free | Yes |
| Clinical Application | Anterior Resection, Bowel Occlusion, Intestinal Anastomosis, Tissue Stabilization |
| Quality Standard | CE & ISO 13485 (Manufacturer Dependent) |
Frequently Asked Questions (FAQs)
1. What is the Glassman Anterior Resection Clamp used for?
It is used to temporarily clamp and stabilize bowel tissue during anterior resection, colorectal surgery, intestinal reconstruction, and gastrointestinal procedures.
2. What is the advantage of the 25 mm serrated tip?
The serrated tip provides a secure grip on bowel tissue while distributing pressure evenly to help minimize tissue slippage and unnecessary trauma.
3. How long is the instrument?
The clamp measures 24.7 cm in overall length, providing excellent access to deep abdominal and pelvic surgical sites.
4. What material is the clamp made from?
It is manufactured from premium surgical-grade stainless steel for exceptional durability, corrosion resistance, and long-term clinical performance.
5. Is the Glassman Anterior Resection Clamp reusable?
Yes. It is designed for repeated professional use after proper cleaning, sterilization, and routine maintenance.
6. Can the instrument be autoclaved?
Yes. It is fully compatible with standard steam autoclave sterilization procedures used in hospitals and surgical centers.
7. Which medical specialties commonly use this clamp?
It is widely used in colorectal surgery, gastrointestinal surgery, and general surgery for bowel resection and intestinal anastomosis procedures.
8. How should the instrument be maintained?
Clean thoroughly after each use, inspect the jaws, serrations, hinge, and ratchet mechanism regularly, and sterilize according to established hospital infection control protocols before reuse.