The Variable Angle Distal Radius Plates 72 Piece Set is a comprehensive orthopedic implant plate and screw system developed for fixation procedures involving distal radius fractures. Designed for use in orthopedic and upper-extremity surgery, this system combines variable-angle locking technology with multiple plate shaft configurations to provide surgeons with flexibility when selecting an appropriate fixation construct.
The system features 5-hole plate heads combined with 3-hole to 7-hole shaft configurations, allowing the selection of different plate lengths according to the fracture pattern, bone anatomy, and fixation strategy. Variable-angle locking screw technology permits controlled screw trajectory selection within the locking interface, providing greater flexibility for fracture fixation and helping the surgical team adapt screw placement to the clinical requirements of the procedure.
Manufactured from stainless steel, these distal radius plates are designed for strength, durability, and resistance to mechanical stresses encountered during orthopedic fixation. Stainless steel construction also provides a robust material platform for repeated handling during surgical preparation and implantation. The plates and associated screws should be used according to the manufacturer’s validated specifications, applicable surgical protocols, and the instructions provided for the particular implant system.
This 72-piece distal radius plate and screw set is particularly suitable for orthopedic departments, trauma centers, surgical hospitals, and medical facilities requiring a versatile selection of distal radius fixation components. Having multiple shaft-hole configurations and corresponding screws organized within one system can help surgical teams prepare for different fracture patterns and operative requirements without relying on a single plate configuration.
The variable-angle design is an important feature for modern distal radius fracture fixation. Rather than restricting every locking screw to one fixed trajectory, a variable-angle locking system can allow the surgeon to select screw direction within the permitted range of the specific implant design. This flexibility can be useful when addressing complex fracture anatomy and when optimizing screw positioning during fixation. Exact permissible angulation and screw compatibility should always be confirmed against the manufacturer’s technical documentation.
The plates are intended for professional orthopedic use and may be incorporated into surgical procedures where internal fixation of the distal radius is clinically indicated. Appropriate plate selection depends on factors such as fracture morphology, bone quality, anatomical considerations, surgical approach, and surgeon preference. The product should be used only by appropriately trained healthcare professionals familiar with orthopedic trauma and internal fixation techniques.
For surgical preparation, the complete system should be inspected to verify that plates, screws, and other components are present, undamaged, and compatible. Proper handling of stainless steel orthopedic implants is important to preserve the integrity of the locking interfaces and screw threads. Components should be cleaned, sterilized, stored, and handled according to the manufacturer’s validated instructions and the healthcare facility’s applicable infection-control procedures. Sterilization parameters should not be assumed solely from the material; the manufacturer’s instructions for use should always take precedence.
For long-term clinical performance, correct implant selection, surgical technique, screw placement, postoperative management, and patient-specific factors are essential. The Locking Distal Radius Plates – Variable Angle system provides a versatile component selection for orthopedic professionals seeking a stainless steel distal radius fixation solution with multiple shaft lengths and variable-angle locking capability.
Key Features
- Variable-angle locking design supports flexible screw trajectory selection within the specifications of the locking interface.
- 5-hole plate head configuration provides multiple fixation points around the distal portion of the radius.
- 3–7 hole shaft options offer different plate lengths for varying fracture and fixation requirements.
- 72-piece system provides a comprehensive selection of plates and screws for orthopedic surgical preparation.
- Stainless steel construction offers a durable material platform suitable for orthopedic implant applications.
- Designed specifically for distal radius fracture fixation and upper-extremity orthopedic procedures.
- Multiple plate configurations help accommodate different fracture patterns and anatomical requirements.
- Locking screw compatibility is designed to create a secure plate-and-screw fixation construct when used according to manufacturer specifications.
- Suitable for use by trained orthopedic surgeons and qualified surgical teams.
- Components should be handled and sterilized according to the applicable manufacturer’s instructions for use and validated sterilization protocols.
- Useful for orthopedic trauma departments, hospitals, surgical centers, and specialized fracture fixation inventories.
- Supports organized surgical preparation by providing multiple distal radius plate and screw configurations within one system.
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Locking Distal Radius Plates – Variable Angle |
| Application | Distal radius fracture fixation |
| Plate Type | Variable-angle locking distal radius plate |
| Head Configuration | 5-Hole Head |
| Shaft Configurations | 3-Hole, 4-Hole, 5-Hole, 6-Hole and 7-Hole options |
| System Quantity | 72 Pieces |
| Material | Stainless Steel |
| Fixation Type | Locking plate and screw fixation |
| Screw System | Compatible locking screws supplied within the set |
| Surgical Specialty | Orthopedic Surgery / Orthopedic Trauma |
| Anatomical Area | Distal Radius / Wrist |
| Intended Users | Qualified orthopedic and surgical professionals |
| Sterilization | Follow manufacturer’s validated sterilization and IFU requirements |
| Packaging | Complete multi-component plate and screw system |
FAQs
1. What are variable-angle distal radius plates used for?
Variable-angle distal radius plates are used for internal fixation of distal radius fractures. Their locking interfaces can provide flexibility in screw trajectory according to the design specifications of the implant system.
2. What does a 5-hole head mean on a distal radius plate?
A 5-hole head indicates that the distal portion of the plate contains five designated fixation holes. These holes provide multiple locations for screw placement in the distal portion of the radius.
3. What shaft sizes are included in this 72-piece system?
The system is specified with 3-hole to 7-hole shaft configurations, providing multiple plate-length options for different distal radius fixation requirements.
4. What material are these locking distal radius plates made from?
The plates are specified as stainless steel. Stainless steel provides a durable material commonly used in orthopedic surgical implant systems.
5. Are screws included with the distal radius plate set?
Yes. The product title specifies a 72-piece system with screws, providing a combined selection of distal radius plates and compatible fixation components.
6. Can variable-angle locking screws be placed at different trajectories?
Variable-angle locking systems are designed to permit controlled variation in screw trajectory within the limits specified by the implant manufacturer. Surgeons should follow the applicable surgical technique and manufacturer documentation.
7. How should stainless steel orthopedic plates and screws be sterilized?
Sterilization should be performed according to the manufacturer’s validated instructions for use and the healthcare facility’s approved sterilization procedures. Specific sterilization parameters should not be assumed without the applicable manufacturer documentation.

Reviews
There are no reviews yet.