The Pediatric LCP Plates 90° (3–6 Holes) with 3.5 mm Screws – Titanium Grade 5 (36 Pcs) are specialized orthopedic fixation components designed to support selected fracture fixation procedures in pediatric patients. The system combines 90° locking compression plate configurations with compatible 3.5 mm screws, providing a range of fixation options for appropriately selected pediatric orthopedic applications.
Pediatric fracture fixation requires careful consideration of anatomy, bone size, fracture characteristics, and the patient’s stage of skeletal development. A dedicated pediatric LCP plate system can provide appropriately configured fixation options while allowing the surgeon to select the plate and screw combination best suited to the specific clinical situation.
The 90° plate configuration is designed for fixation situations where an angled plate geometry is appropriate. The exact anatomical application depends on the specific plate design, dimensions, contour, and manufacturer’s intended use. The 3–6 hole configurations provide multiple plate lengths, allowing the surgeon to select an appropriate fixation span based on fracture location and available bone.
The system incorporates locking plate technology, in which compatible locking screws engage with threaded plate holes to create a fixed-angle relationship. This can provide angular stability within an appropriately designed fixation construct. The exact locking mechanism, screw trajectory, and permitted surgical technique should always be verified using the manufacturer’s instructions for use.
The plates and screws are specified as Titanium Grade 5. Titanium Grade 5, also known as Ti-6Al-4V, is widely used in orthopedic implant applications because of its high strength-to-weight ratio, corrosion resistance, and established biocompatibility. The exact material certification and applicable implant standards should be confirmed from the manufacturer’s technical documentation.
The 36-piece configuration provides multiple plate and screw options in one organized system. This can be useful for orthopedic hospitals, pediatric trauma centers, surgical facilities, and medical distributors managing a range of fixation requirements.
Before implantation, each component should be inspected for damage, deformation, corrosion, surface defects, or compromised packaging. Only compatible screws and instruments should be used with the plate system. Implant components should be handled according to the manufacturer’s instructions and applicable medical-device requirements.
Implantable plates and screws are generally intended for single-patient use unless the manufacturer specifically states otherwise. Used, damaged, or compromised implant components should not be reused or reprocessed for implantation.
The Pediatric 90° LCP Plate System is intended for use by qualified orthopedic and pediatric orthopedic surgeons trained in fracture fixation. Plate selection, positioning, screw placement, reduction, and postoperative management should be determined by the surgeon based on patient anatomy, fracture morphology, bone quality, skeletal maturity, and the manufacturer’s surgical technique.
This product is suitable for professional orthopedic facilities seeking a compact titanium Grade 5 pediatric locking plate and screw system for selected fracture fixation applications.
Key Features
- Pediatric 90° LCP plate system
- 3–6 hole plate configurations
- Compatible 3.5 mm locking screws
- Titanium Grade 5 construction
- 36-piece complete configuration
- Designed for selected pediatric orthopedic fixation
- Locking screw technology for angular stability
- Multiple plate lengths for fixation flexibility
- Lightweight titanium implant material
- Suitable for orthopedic trauma applications
- Professional implant system configuration
- Intended for qualified orthopedic surgeons
Product Specifications
| Specification | Details |
|---|---|
| Product Type | Pediatric LCP Plate & Screw Set |
| Plate Design | 90° Locking Plate |
| Hole Configuration | 3–6 Holes |
| Screw Diameter | 3.5 mm |
| Application | Pediatric Fracture Fixation |
| Specialty | Pediatric Orthopedic / Trauma Surgery |
| Material | Titanium Grade 5 |
| Total Quantity | 36 Pieces |
| Screw Type | Compatible Locking Screws |
| Sterilization | According to manufacturer/device instructions |
| Reusability | Implant components intended for single-patient use |
| Usage | Internal Bone Fixation |
| Finish | Medical Implant Finish |
Product Contents
The 36-piece configuration includes a combination of:
- 90° pediatric LCP plates
- 3-hole plate configurations
- 4-hole plate configurations
- 5-hole plate configurations
- 6-hole plate configurations
- Compatible 3.5 mm titanium Grade 5 locking screws
- Supporting fixation components according to configuration
Total: 36 Pieces
Exact plate quantities, screw lengths, and individual component counts should be confirmed against the manufacturer’s packing list.
Applications
The pediatric LCP plate system may be used for selected:
- Pediatric fracture fixation
- Pediatric orthopedic trauma procedures
- Metaphyseal fracture fixation
- Diaphyseal fracture fixation where appropriately indicated
- Angular fixation procedures
- Internal fixation of selected long-bone fractures
- Pediatric reconstructive orthopedic procedures
Specific indications depend on the plate design, regulatory approval, manufacturer’s instructions for use, patient anatomy, skeletal maturity, and surgeon assessment.
FAQs
1. What are pediatric 90° LCP plates used for?
They are designed to support selected pediatric fracture fixation procedures where a 90° locking plate configuration is appropriate.
2. How many pieces are included?
The stated configuration contains 36 pieces, including plates and compatible 3.5 mm screws.
3. What plate sizes are available?
The set includes 3–6 hole configurations, providing different plate lengths for fixation requirements.
4. What material are the plates and screws made from?
The product is specified as Titanium Grade 5, commonly known as Ti-6Al-4V.
5. What screw size is included?
The system uses 3.5 mm compatible locking screws. Exact screw lengths should be confirmed from the manufacturer’s packing list.
6. What does LCP mean?
LCP stands for Locking Compression Plate. Compatible locking screws engage with threaded plate holes to provide a fixed-angle fixation construct.
7. Can these implants be reused?
No. Implantable plates and screws are generally intended for single-patient use unless the manufacturer specifically states otherwise.
8. Who should use this pediatric LCP system?
The system is intended for qualified orthopedic and pediatric orthopedic surgeons trained in pediatric fracture fixation and familiar with the manufacturer’s surgical technique.

Reviews
There are no reviews yet.