The Zimmer Hall 7020-200 Ultra Power Neuro/Spine System Sterilization Tray is a dedicated storage and sterilization solution associated with the Hall UltraPower Neuro/Spinal surgical drill system. The UltraPower 7020-200 configuration is identified for neuro and spinal surgery applications, while the corresponding Neuro/Spinal autoclave case provides an organized platform for processing compatible system components.
A dedicated sterilization tray is particularly useful for powered neurosurgical equipment because drill handpieces, guards, angle attachments, wrenches, hoses, and related accessories can be difficult to manage when stored separately. Keeping compatible components in a defined tray configuration can help reduce the risk of misplaced parts and make preoperative inspection and postoperative accounting more systematic.
The tray is associated with the Hall UltraPower Neuro/Spinal System, which includes components such as high-speed and low-speed handpieces, a perforator drive, neuro guards, burr guards, angled attachments, and other accessories depending on the system configuration. The exact contents placed in the tray may vary according to the kit or inventory being processed.
Proper organization is important for powered surgical equipment used in neurosurgery and spine surgery. Dedicated storage positions can help keep handpieces and attachments separated, reducing unnecessary contact between precision components. This is especially relevant for cutting accessories, drive interfaces, attachment mechanisms, and other parts that require careful inspection before clinical use.
The tray can support sterile-processing workflows by providing a defined location for compatible reusable system components. A standardized arrangement makes it easier for sterile processing personnel to identify instruments, check completeness, perform cleaning and inspection, and prepare the set for subsequent sterilization.
According to the UltraPower documentation, cleaned instruments may be placed in designated instrument trays, including the Neuro/Spinal case identified as 7020-052. The manufacturer’s documentation also provides specific steam sterilization parameters for Neuro/Spinal kits in that case.
The exact sterilization cycle should always be determined from the validated instructions applicable to the specific components being processed. Powered handpieces and attachments may have component-specific requirements involving cleaning, lubrication, drying, inspection, and sterilization. Electrical or non-sterilizable control components should not be processed in the same manner as reusable surgical handpieces unless expressly approved.
The tray should also be inspected routinely for structural damage, cracks, deformation, compromised retention features, or other defects that could interfere with proper instrument organization. A damaged tray may not adequately protect precision surgical components during transport, storage, or sterilization.
Because the product is associated with a named surgical power system, compatibility should be confirmed before use. The 7020-200 reference identifies the UltraPower Neuro/Spinal System, while individual components and storage cases have their own reference numbers. Matching the tray or case to the correct system configuration helps ensure that instruments are stored and processed using the appropriate validated setup.
The Zimmer Hall UltraPower Neuro/Spine Sterilization Tray is suitable for hospitals, neurosurgical departments, spine surgery centers, sterile processing departments, and medical facilities maintaining compatible Hall UltraPower neuro and spinal drill equipment. Its primary function is organized storage, protection, and applicable sterilization of reusable system components.
Key Features
- Designed for Hall UltraPower Neuro/Spinal system components
- Associated with the 7020-200 Neuro/Spinal system
- Supports organized storage and instrument processing
- Suitable for compatible drill handpieces and attachments
- Helps protect precision surgical components during handling
- Useful for neurosurgical and spine surgery instrument management
- Supports systematic sterile-processing workflows
- Helps simplify instrument counting and set completeness checks
- Dedicated configuration reduces loose component storage
- Suitable for hospital and surgical-center environments
- Tray condition should be inspected before use
- Sterilization must follow validated manufacturer instructions
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Zimmer Hall UltraPower Neuro/Spine Sterilization Tray |
| Associated System | Hall UltraPower 7020-200 Neuro/Spinal System |
| Tray / Case Reference | 7020-052 Neuro/Spinal Autoclave Case |
| Product Type | Surgical Instrument Sterilization / Storage Case |
| Primary Specialty | Neurosurgery / Spine Surgery |
| Main Function | Storage, Organization and Sterilization Support |
| Compatible Components | Handpieces, Guards, Attachments and Accessories |
| Application | Neuro / Spinal Powered Surgical System |
| Processing | Validated Sterilization Workflow |
| Material | Case Construction, Model Dependent |
| Capacity | System Configuration Dependent |
| Internal Layout | Dedicated / Configuration Dependent |
| Reusable | Yes, When Labeled for Reuse |
| Sterilization | Follow Validated Manufacturer Instructions |
| Compatibility | Verify Exact UltraPower Components Before Processing |
FAQs
What is the Zimmer Hall 7020-200 sterilization tray used for?
It is associated with the Hall UltraPower Neuro/Spinal system and is intended to organize, protect, and support processing of compatible reusable surgical drill components.
What is the difference between 7020-200 and 7020-052?
The 7020-200 reference identifies the UltraPower Neuro/Spinal System, while 7020-052 identifies the Neuro/Spinal autoclave case used for processing compatible system components.
What components can be stored in the Neuro/Spinal tray?
Depending on the kit configuration, compatible components may include handpieces, neuro guards, burr guards, angle attachments, wrenches, and related accessories. The exact loaded configuration should be verified for the specific system.
Is this tray designed for neurosurgery?
Yes. The associated 7020-200 UltraPower system is specifically identified as a Neuro/Spinal System and is intended for neuro and spinal surgical applications.
Can the tray be used for spine surgery?
It is associated with the Neuro/Spinal configuration of the UltraPower system and can support organization and processing of compatible equipment used in spine surgery.
Why is a dedicated sterilization case useful for powered surgical instruments?
A dedicated case keeps related components together, protects precision parts during handling, and supports more systematic cleaning, inspection, counting, and sterilization workflows.
Can any Hall UltraPower component be placed in this tray?
Components should only be placed in the tray when they are compatible with its configuration and the applicable manufacturer instructions. Exact tray loading should be verified before processing.
Is the tray reusable?
The case may be reusable when it is designed and labeled for repeated clinical processing. Its condition and applicable manufacturer instructions should be checked before each use.
How should the Neuro/Spinal tray be sterilized?
Sterilization should follow the validated manufacturer instructions for the exact Neuro/Spinal case and the components being processed. The UltraPower documentation provides specific steam-processing parameters for Neuro/Spinal kits in the designated case.
What should be checked before using the tray?
Inspect the tray for cracks, deformation, damaged retention features, contamination, and other defects. Also verify that the correct UltraPower components are being processed in the appropriate configuration.
Does the tray include the complete UltraPower drill system?
Not necessarily. A sterilization tray or case is a storage and processing component; the included surgical handpieces, attachments, guards, and accessories depend on the specific product listing and configuration.

Reviews
There are no reviews yet.