The 10″ DeBakey Renal Artery Clamp Angled Jaw is a precision-engineered vascular surgical instrument designed for controlled handling and temporary occlusion of renal arteries during complex surgical procedures. Featuring a DeBakey atraumatic jaw design, curved shank, and angled jaw configuration, this clamp provides surgeons with enhanced access, precise positioning, and dependable vascular control.
The DeBakey Renal Artery Clamp is specifically designed for delicate vascular applications where accurate manipulation and gentle tissue handling are essential. Its specialized construction allows surgeons to isolate and control renal vessels while helping minimize trauma to surrounding vascular structures. This makes it an important instrument for procedures involving renal artery repair, reconstruction, and vascular surgery.
The curved shank design improves surgical versatility by allowing the instrument to approach anatomical structures from an optimized angle. This feature provides better access in confined operative areas and supports improved visibility during procedures involving deeper vascular anatomy. The curved profile helps surgeons position the clamp effectively while maintaining precise control.
The angled jaw configuration enhances maneuverability by allowing controlled engagement with vessels from a lateral approach. This design is particularly beneficial when working around complex anatomical structures where straight clamps may provide limited access. The angled jaws support accurate placement and efficient vessel management during delicate procedures.
With a 10-inch length, this renal artery clamp provides excellent reach while maintaining balance and control. The extended design allows access to deeper surgical sites while preserving tactile feedback and handling precision. Its ergonomic construction supports comfortable use during longer cardiovascular and vascular procedures.
The DeBakey atraumatic jaw pattern is engineered to provide secure vessel control while reducing unnecessary pressure on delicate tissues. The jaw surface helps distribute compression evenly, allowing surgeons to maintain stable occlusion while supporting careful vascular handling. This makes the instrument suitable for renal artery procedures, vascular reconstruction, and other specialized applications.
Manufactured from high-quality surgical-grade stainless steel, the 10″ DeBakey Renal Artery Clamp Curved Shank Angled Jaw offers exceptional durability, corrosion resistance, and long-term reliability. The robust stainless steel construction allows repeated cleaning, disinfection, and sterilization cycles while maintaining precise jaw alignment and smooth mechanical performance.
The ergonomic ring handle design provides surgeons with improved comfort and control. A secure locking mechanism allows consistent clamping pressure to be maintained after placement, supporting efficient workflow during critical surgical procedures. Smooth ratcheting action ensures reliable instrument function.
This renal artery vascular clamp is commonly used in vascular surgery, renal procedures, cardiovascular reconstruction, and other operations requiring controlled arterial manipulation. Its long reach, curved shank, and angled jaw design make it a valuable tool for surgeons working in complex anatomical regions.
Proper cleaning, inspection, and sterilization according to professional surgical instrument guidelines are essential for maintaining performance and extending instrument life. Routine evaluation of jaw function and locking mechanism helps ensure consistent reliability.
The Cardiovascular Instrument 10″ DeBakey Renal Artery Clamp Curved Shank Angled Jaw combines precision engineering, atraumatic vessel handling, and durable construction to provide surgeons with a dependable instrument for advanced vascular procedures.
Key Features
- Precision 10″ DeBakey Renal Artery Clamp for vascular procedures
- Curved shank design improves access and surgical positioning
- Angled jaw configuration supports controlled vessel engagement
- DeBakey atraumatic jaws help minimize vascular tissue trauma
- Designed for renal artery control and vascular manipulation
- Extended length provides improved reach in deep surgical fields
- Suitable for cardiovascular and vascular reconstruction procedures
- Manufactured from premium surgical-grade stainless steel
- Corrosion-resistant construction supports repeated sterilization
- Ergonomic handle enhances surgeon comfort and control
- Locking mechanism maintains consistent clamping pressure
Product Specifications Table
| Specification | Details |
|---|---|
| Product Name | Cardiovascular Instrument 10″ DeBakey Renal Artery Clamp Curved Shank Angled Jaw |
| Instrument Type | Renal Artery Vascular Clamp |
| Overall Length | 10 Inches |
| Jaw Design | Angled Jaw |
| Shank Design | Curved Shank |
| Jaw Style | DeBakey Atraumatic |
| Application | Vascular and Cardiovascular Surgery |
| Primary Use | Renal Artery Control and Vessel Occlusion |
| Material | Surgical Stainless Steel |
| Handle Type | Ring Handle with Locking Mechanism |
| Reusable | Yes |
| Sterilization Compatibility | Standard Surgical Sterilization Methods |
FAQs
1. What is the 10″ DeBakey Renal Artery Clamp used for?
This clamp is used for controlled manipulation, temporary occlusion, and handling of renal arteries during vascular procedures.
2. What is the benefit of a curved shank design?
A curved shank improves access and allows surgeons to position the instrument around complex anatomical structures more effectively.
3. Why are angled jaws useful in renal artery clamps?
Angled jaws allow improved vessel approach and positioning when working in confined surgical areas.
4. Are DeBakey renal artery clamps atraumatic?
Yes, DeBakey-style jaws are designed to provide secure vessel control while helping minimize tissue trauma.
5. Is this renal artery clamp reusable?
Yes, it is manufactured from surgical-grade stainless steel and designed for repeated cleaning and sterilization.
6. Which procedures use renal artery clamps?
They are commonly used in vascular surgery, renal artery repair, reconstruction procedures, and cardiovascular applications.
7. How should this DeBakey vascular clamp be maintained?
The instrument should be cleaned, inspected, and sterilized according to professional surgical instrument care guidelines to maintain optimal performance.

Reviews
There are no reviews yet.